HouseLinc versions

It allows you to set up and manage all the home automation devices in your home
2.9
Jan 24, 2012
Review
2.8
Nov 19, 2011
2.7
Sep 28, 2011
2.6
Jun 15, 2011
2.5
Mar 29, 2010
2.1
May 24, 2013
2.0
Oct 28, 2009
Review

What's new

v2.9 [Jan 24, 2012]
- Adjusted default ramp rate and scene settings for new INSTEON LED Bulb 8-Watt (60W)
- Fixed ramp rate for new INSTEON LED Bulb 8-Watt (60W)
- Added support for new INSTEON LED Bulb 8-Watt (60W)
- Added support for Switchlinc ON/OFF 2477S
- Added support for new INSTEON Thermostat and INSTEON Wireless Thermostat
- Added support for SwitchLinc 2-Wire Dimmer
- Added support for more checksum products: Thermostat, Integrated Thermostat, SynchroLinc, iMeter, MorningLinc, IRLinc Receiver, IRLinc Transmitter, SmartLinc2
- Added event trigger support to Thermostat and Integrated Thermostat
- Added option to send email when a PLM connection error occurs
- Removed MorningLinc's lock and unlock triggers because it does not support this feature
- Fixed UI issue when manually changing a Gateway
- Fixed sharing emails between the original and copies of an event
- Added support for Smarthome IP Camera 75790
- Fixed a bug that immediately starts database sync immediately when a scene member is removed
- Added ability to duplicate an event (Right-click on an event and select Duplicate Event in the pop-up menu. The newly duplicated event is appended to the end of the list and is disabled by default
- Fixed the Events list to retain the focus on the selected event after editing it
- Remove the PLM links when a Scene is removed from an event if the PLM group was not part of the scene prior to adding to the event
- Fixed setting the default property values for KeypadLinc, Motion Sensor, 2-button RL2
- Fixed flickering when changing a keypad button name
Stopped setting Load Sense flag to SwitchLinc
- Changed format of a scene's last trigger information to "DateTime, Command, Number of Errors"
- Change input focus to the event name field when adding a new event
- Fixed the Refresh button for RemoteLinc 2 Propeties to display the battery-powered device information
- Fixed sorting of the broadcast timestamp in Scenes list
- Fixed setting pre-scaler for Momentary time
- Changed Refresh button to Write To Device
- Added support for updating the cameras definition
- Add support to search for Foscam IP Camera Model FI8918W
- Crash with camera delete - Several instances of similar crash in the log files - see additional info section
- Move PLM controller links to the top of the link table fixed synchronizing device after factory reset
- HL settings will always win in property sync to a device
- Fixed version warning message on TouchLinc after deploying the configuration
- Fixed an issue that stopped displaying generic INSTEON devices in the Device List
- Fixed sending X10 All Lights On/Off command
- Added IP Camera support in HouseLinc
- Added support for X10 products
- Added support for InlineLinc On/Of Dual Band and 50/60 version
- Added support for updating Cameras definition – through server push
- Fixed KeypadLinc backlight brightness being set to 2% during synchronization
- Fixed PLM links not being created for group 2, 7 and 8 on KeypadLinc after changing from 6- to 8-button
- Added an option to change the number of firmware retry in Tools | Options | System, Controller Link App-Retry. The default value is 3
- Fixed a crash when changing from 6- to 8-button on I1 Keypad
- Resolved an issue with synchronizing properties of Motion Sensor and SynchroLinc
- Fixed KeypadLinc back light brightness being set to 2%
- Fixed an issue when changing from 6- to 8-button on i1 KeypadLinc
- Added support to send INSTEON message in an Event - Sending Customer INSTEON Commands
- Added hyperlink in the Custom Commands dialog box with http://www.smarthome.com/insteon-custom-commands.html
- Added option to disable a device under the Properties tab
- Added Time Stamp to links. Located in the Advanced Tab for any newly created links
- Added ID column to Scene Editor
- Added support for RemoteLinc 2
- Added support for setting LED level for SwitchLinc and InlineLinc in Events
- Added double confirm to all property reads. The returned value is accepted only if it matches with HouseLinc value; or 2 consecutive reads returned the same data
- Added tasks persistence: save the task queues on shutdown and continue with them on startup
- Added Queue task count information to the Status Bar- Provides Visibility of what task is currently running and how many are left (x / y)
- Auto-populate Date Added field when adding a device
- Improved database sync process
- Improved properties sync process
- Improved synchronizing a battery operated device
- Improved adding device process
- Improved deleting device process
- Changed event with Security feature to be triggered once-per-day randomly in the specified time frame instead of at-least-once
- Changed text in event for button pressed events to "Double-Tapped"
- Changed the Scene list to sort alphabetical by name by default
- Fixed scroll bars in Scene editor
- Fixed the Update dialog box being displayed behind HouseLinc window sometimes
- Fixed the Pause button functionality in the Status bar
- Removed the ability of the OutletLinc Relay to be a controller
- When deleting a TouchLinc device, also delete its configuration files
- Resolved check box disappearing in Scene editor. It should now happen less often
- Fixed excessive retry when a device is unplugged in the middle of database synch
- Fixing the ID column in Device List not being re-sizable
- Fixed issue with managing i1 KeypadLinc devices button properties (Toggle/ON/OFF)
- Fixed 8-button keypad being displayed as a 6-button
- Fixed Keypad button mode being displayed differently sometimes in Properties tab vs. Device List and Scene List
- Fixed a crash when clicking on Keypad button G or H after switching from 6 to 8 button
- Fixed half link to PLM group 0 (only at the end of the PLM database sync)
- Fixed a problem with Motion Sensor LED brightness cannot be changed by 1%
- Fixed triggering events based on RL2 button press
- Fixed missing PLM links to the new RL2 button when switching from 1-button to 2-button or from 4-button to 8-button
- Fixed changing KeypadLinc button mode under the Links tab
- Added support for Integrated Thermostat in Scene editor
- Added support for 2-button RemoteLinc 2
- Updated User Interface and graphics
- Added support for TouchLinc TouchLinc
- Added Scene Management
- Included SceneConverter.exe in the setup and install it into the Settings folder
- Added abilities to change local On Level, Ramp Rate, LED, and other properties for applicable devices
- Added sortable Room column to the link display in Links tab
- Fixed beeping a device more than twice the specified number of seconds
- Removed checking status of battery-operated devices
- Updated sounds used when adding a device
- Fixed a bug in the Advanced tab that sometime did not show the information of the current selected device
Prevented selecting invalid thermostat set points (cool set point must be at least 2 degrees higher than heat set point)
- Fixed inconsistent thermostat group names between the Device List and the Links tab
- Added an option to enable or disable Thermostat status reporting in the Properties tab. HouseLinc will not automatically create this link from now on
- The Advanced tab is now hidden on start-up. It can be revealed by selecting the Show Advanced Tab option in Tools | Options | System
- Changed setting device status in Properties tab to Unknown every time a device is selected. Device status is only updated when clicking on the Refresh button or one of control buttons
- Disabled HouseLinc Maintenance event by on new install and upgrade
- Added FTDI driver setup and install it if needed
- Added support for iMeter Solo
- Fixed a problem that did not always trigger an event
- Added support for TouchLinc
- Added auto-restart if the application encounters unexpected problem
- Added email retries (up to 3 retries)
- Updated product images for USB Stick, In-LineLinc, and LampLinc (Dual-Band)
- Corrected problem with loss of event information while saving settings
- Included Beep command under the Control/Status tab for devices that have beepers
- Added support for MorningLinc RF Doorknob/Deadbolt Controller (#2458A1)
- Added support for 240V 30AMP Load Controller (#2477SA1 and 2477SA2)
- Swap command now updates device ID in both Links and Events tab
- Info tab now displays the product page of a selected device
- Changed the I/O Linc Control page to include both Open Relay and Closed Relay options, even when I/O Linc is in Momentary Mode
- Many UI enhancement and performance improvements
- Fixed RemoteLinc rapid battery depletion issue.
- Added support for FTDI Virtual COM Port driver version 2.06.
- Added email alert feature. Users now can set up an event to send email to their email accounts.
- Added support to update Devices.xml automatically
- Added a new driver for I/O Linc with Firmware 0x33 or newer to support longer momentary delay settings.
- Digitally signed HouseLinc and the installer to identify SmartLabs as the publisher on Windows Vista and newer
- Centralized data (device definitions, settings and logs) location to better support online updates.
- Removed 9 minute ramp rate option as the Firmware no longer supports it
- Prompt to synchronize devices upon startup
- Improved Thermostat Adapter User Interface
- Improved Installer wizard
- Fixed bugs in Diagnostics tool
- Updated Device Definition file to cover more devices.
- Added support for TriggerLinc firmware revision 0x28
- Added new firmware revisions: 0x38
- Added new firmware revisions: 0x37
- SwitchLinc 220V Relay added
- SmartLinc with firmware 7A
- Firmware 37 in I2.1 devices
- PLM 0x85
- Remotelinc 0x80
- Added new PLM support
- Dark and light outside conditions fixed.
- Minor UI improvements.
- Improvements in communication with devices, including battery operated devices.
- Manual configuration wizard fixes.
- Fixed some device revisions that were not recognized properly.
- HouseLinc now backs up several revisions of the settings file.
- I/O Linc support
- More device support
- Fixed problem with HouseLinc crashing during maintenance
- Allow both Motion and Motion timed out to be used in events individually
- Support for Motion Detector
- Minor UI updates and bug fixes
- More device support
-

Alternative downloads

QuickBooks Pro Timer
QuickBooks Pro Timer
Free
rating

Quickbooks itself can store details of your customer and their jobs.

Haunted House Horrors
Haunted House Horrors
Free
rating

Enjoy this scary horror screen saver in your desktop for free.

Karen's Countdown Timer II
Karen's Countdown Timer II
Free
rating

It will remember you all events and informs you on time about the events.

Nightmare House
Nightmare House
Free
rating

Small map pack for Half Life 2, which contains 4 maps.

Namaaz Timer
Namaaz Timer
Free
rating

Namaaz Timer software recites Adhans at the correct times.